Mounting methods for flush-type connectors
Please select:
Front mounting, cannot be positioned
Device connectors are available with M16 or PG9 fastening threads and have 0.5 m long individual wires.

The mounting section must then be adapted to the connector contour.

With their compatibility with the M23 device connectors, the M12 connectors/sockets can be easily integrated into existing housing constructions.

Front mounting, can be positioned
Device connectors are fixed into the housing wall and positioned.

These variants are available with M16 or PG9 fastening threads and have 0.5 m long individual wires.

The angular connector can be positioned freely and fixed at the side of a device into a standard M12 x 1 thread.

Rear mounting - with litz wires and solder contacts
In this version, the key surfaces of the fastening thread can optionally be used as protection against rotation.

The solder versions are available with different contact lengths and shield contacts for fieldbus applications.

The IP20 compatible I/O connectors that have been specially designed for sensors are included in the COMBICON product range.

Wave soldering and THR PCB assembly
The process-optimized geometry and the machine-capable tray packaging guarantee optimum processing in the Pick & Place mounting process. Contact carriers suitable for wave soldering are clipped on the board manually and then soldered. The mounting procedure is identical for both connector types.

As an alternative to customer-specific housings, the M12 screw connection can often be directly integrated into the housing contour. The M8/M12 sensor/actuator flush-type connectors comply with IEC 61076-2-101.